TR8 Odotracker
Handheld Analyzer & Chemical Tracker

TR8 Odotracker Handheld Analyzer is a multi-sensor analysis tool that measures the concentrations of two chemicals in ambient air at the same time.

Overview

The Odotracker Handheld Analyzer is a multi-sensor analysis tool that measures the concentrations of two chemicals in ambient air at the same time. Chemicals to be measured by the device are specified at the time of ordering. As a result, the user may specify the measurement of Hydrogen Sulphide (H2S) at ppb-level and Ammonia (NH3) at ppm-level. The TR8 Odotracker is an incredibly helpful tool, because it logs the chemical measurements as well as temperature and humidity of the sample, GPS location, and automatically transfers all data to the user’s supplied smart android device via Bluetooth.

A TR8 Odotracker Handheld Analyzer Includes a sampling pump, two chemical sensors that are specified at the time of ordering, and Scentroid’s OdoTracker Application that can be loaded to any customer supplied android phone/tablet. for each sample location, Scentroid instantaneously records:

  • Concentration of two chemical vapours in ppm or ppb depending on sensors ordered
  • Temperature and humidity
  • GPS position of each measurement
  • Continuously for remote monitoring via Bluetooth

Detection Threshold

TR8 Odotracker measures chemicals close to the detection threshold at parts per billion (ppb) levels

Automated Data Logging

The TR8 Odotracker provides automated continuous chemical, GPS position, temperature, and humidity data logging

Reporting Standards

Traceable back to international standards: e.g. USEPA (40 CFR part 53) and EU (2008 / 50 / EC)

Companion Equipment

An Odotracker works great with a personal olfactometer, such as the SM100i. This allows users to determine the concentration of chemical compounds as well as ambient odours

Increased Safety

by providing a constant reading of ambient air, users will receive added protection from over exposure to chemical vapours

Manage Odour Losses

Laboratories can manage odour degradation through sample transportation and storage by analyzing values live and in-field instead

Measure ambient H2S, Ammonia, Total VOC, and other chemical concentrations
Determine H2S, Ammonia, VOCs, and other chemicals emissions from various types of sources
Determine emission trends through 24+ hour data logging
Verify sample loss due to transportation
Validate dispersion models through emission measurements

Connect to OdoTracker via Bluetooth
Connect the sample bag or allow for ambient air to be pulled in
See chemical readings live
Take snapshot readings of H2S, Ammonia, VOC, another chemical compositions, GPS position, Temperature, and humidity of the sample
Activate recording for continuous data logging
Export data for reporting and post analysis

OdoTracker can be used to record chemical vapours, along with the intelligent personal olfactometer SM100i to do odour concentration measurements, providing simultaneous measurements on one android device.

Odotracker will provide the user with a constant reading of the ambient air providing an added protection from over exposure to chemical vapours such as hydrogen sulphide.

Laboratories can utilize the Odotracker to manage odour losses in sample transportation and storage. for example H2S and NH3 readings after sampling and before olfactometric analysis will allow the laboratory determine the level of odour losses and determine if the sample is still valid.

Odotracker can accommodate an optional controller module that has a 10 amp dry contact relay output to signal if the summation of the customer specified combined scaled chemical readings exceeds a customer specified threshold setting. This relay contact can be used to trigger alarms or switch on ventilation fans, chemical scrubbers or other devices when a combined scaled chemical concentration for the two sensors is reached. A hysteresis span is provided for relay triggering and non-triggering.

Sensors:

Maximum Sensors: 10 (Click here for full sensor list)
Type of Sensors: PID, NDIR, EC, Laser Particulate Counter, MOS

Sampling:

Sampling Rate: Adjustable from 1/s to 1/m
Sampling Ports: 1 to 2
Sampling Range: Range depends on active sensors
Initiation Time: 2 minutes
Settling Time: 0.5 seconds
Pressure Range: 80 – 120 kPa
Additional Parameters Measured: Temperature, relative humidity, GPS position 

Power:

Battery Life: 24 hours

Communications:

Communication: Bluetooth connection with any android device

Temperature:

Temperature Range: -30 to 50 °C
Humidity Range:  15 – 90% relative humidity

Calibration:

Manual Calibration: Using calibration gas and on-board screen
Automatic Calibration: Optional, using built-in calibration gas

Warranty:

Warranty: 24 months full warranty on all parts including sensors
Sensor Replacement: Sensor dependent; first 2 years are covered by warranty

Hardware:

Casing: Heavy duty pelican case ensures components are kept safe 

Got any Questions?
Call us Today!

(+603) 7845 4566

asma@enviromalaysia.com.my

At ASMA, all employees possess the highest standard of self-regulation as well as corporate governance and integrity.

We exercise a zero-tolerance policy towards any acts of corruption or bribery. Conforming to our commitment in conducting a corruption-free business that adheres to the Malaysian Anti-Corruption Commission Act 2009, we have adopted the "No Gift Policy" and the "Anti-Bribery and Corruption Policy" which prohibits our employees from soliciting or receiving any form of gratification from vendors, customers and other external parties. Such policies shall also apply to all of ASMA's vendors, suppliers, contractors and consultants.